Lab technician
Run daily IQC and analyzer start-up, receive or reject samples, process and report, log critical values and deliver reports.
Lab technician
Who this is for
You are a Lab technician (technologist). You keep the analyzers in control and move samples through the lab. Your role can:
- register orders and mark samples collected,
- receive, process and report,
- reject a sample, or cancel an order,
- flag critical values,
- mark verified reports Delivered.
You cannot verify a report. That is the pathologist's sign-off.
What you see
Bottom tab bar: Home, Tasks, Scan, Diagnostics and More.
More sheet: Notifications; Clinical → Diagnostics; Work → My Team Dashboard, Corrective Actions, My History, Overall Histories; Biomedical & facility → Equipment, Work orders; then My account, User manual and Help center. You have no Manage group and no Patients.
Your day
- Before the first patient run, open Tasks and complete Analyzer Start-up & Daily Maintenance, then Daily Internal QC (Westgard), for each analyzer.
- Do the Reagent & Lab Fridge Log (twice a day if it is assigned twice).
- Open Diagnostics → In progress. Receive each new sample, or reject it.
- Process and report. STAT and Urgent orders sit at the top of the list.
- Phone and log any critical value straight away.
- Mark verified reports Delivered as they are handed over (the Ready chip lists them).
- If an analyzer fails, raise a work order (More → Work orders → + New). See Equipment breakdown.
Step by step
Run daily IQC (Westgard)
- Tasks → tap Start on Daily Internal QC (Westgard).
- Fill in Analyzer / section, Control lot number, Level 1 result and Level 2 result.
- Answer Pass, Fail or N/A for:
- Within ±2 SD (no 1-2s warning)
- No Westgard rejection rule violated (1-3s, 2-2s, R-4s, 4-1s, 10x)
- Levey-Jennings chart updated
- If you answer Fail, describe what happened and add a photo. Write what you did in Corrective action taken (if out of control). Do not release patient results until the run is back in control.
- Under Technologist, type your full name and sign in the box.
- Tap Submit inspection.
The pass mark is 100%. Every Fail becomes a deviation that your manager reviews. The next day's task is created automatically when you submit.
Analyzer start-up
- Tasks → Analyzer Start-up & Daily Maintenance → Start.
- Fill in the Analyzer field.
- Answer: Start-up / prime completed, Reagents loaded and in date, Calibration valid, Probes and wash station cleaned, Waste container emptied, Room temperature (°C) and No error flags on the instrument.
- Sign under Technologist and tap Submit inspection.
Tip: Copy answers from last time fills in yesterday's answers. Check every one before you submit.
Receive a sample
- Scan the tube label from Scan, or search the accession number in Diagnostics.
- Check the sample against the requisition. If your lab uses it, tap Add checklist → Sample Receiving & Rejection Check → Add to order, then run it.
- Tap Mark as received in lab.
Reject a sample
- On the order, tap Reject / cancel.
- Choose Reject sample (recollect).
- In Reason, pick one from the list: Haemolysed, Clotted, Insufficient volume, Wrong container / tube, Unlabelled or mislabelled, Delayed transport or Leaked / broken container. You can also type your own.
- Tap Close order and confirm.
The order closes as Rejected and its open checklists close too. For the recollection, register a new order (+ New order) and print a new label.
Process and report
- Tap Mark as processing when the sample goes on the analyzer.
- Tap Mark as reported when the results are entered.
The order now waits for a pathologist. The page says waiting for a pathologist / lab manager.
Log a critical value
- Repeat or re-check the result, then phone the referring doctor and ask for a read-back.
- On the order, open Flag critical value (from Processing onwards).
- Fill in Notified to (name, role) and, if the call was earlier, Time notified.
- Tap Save critical value call.
Pathologists, the lab manager, administrators, the quality manager and the medical director are alerted. See Critical value workflow.
Deliver a report
- Diagnostics → Ready lists verified orders.
- Open the order, hand over the report and tap Mark as delivered.
What you can't do
| Task | Who does it |
|---|---|
| Mark as verified | Pathologist, lab manager |
| Assign or schedule checklists | Lab manager, quality manager, administrator |
| Delete order | Managers only |
| Approve a checklist | Managers (Approvals) |
Try it